Acute ADP1100-U Differential probe

The Acute ADP1100-U is an active 700V differential probe with 100 MHz bandwidth.

€500.00*

Delivery time: 1 week

Further information
Model
Request a quote
Paypal-icon
Mastercard-icon
visa-icon
klarna-icon
Sepa-lastschrift-icon
invoice-icon
Product number: ADP1100-U
Manufacturer: Acute

Description

The active ADP differential probes from Acute, with measuring ranges up to +/-3500V, are a useful addition to many PC oscilloscopes.

The ADP-1100/2100/5100 active differential probes offer a maximum bandwidth of 100MHz with a switchable bandwidth limit of 5MHz or FULL.

All models can be supplied with power via USB connection, e.g. of an oscilloscope, the -B models also have a battery included in the scope of delivery. For oscilloscopes without a USB port, a USB power pack can also be plugged in, see data sheet.

In addition, the probes have measuring ranges of +/-700V (DC+ pk AC), +/-1400V (DC+ pk AC) or +/-3500V (DC+ pk AC) with a protective circuit of 2500V, 4000V or 6000V, an integrated overvoltage protection display with an integrated overvoltage protection indicator, and a battery.integrated overvoltage protection display with simultaneous audible alarm in the event of an overrange and switchable attenuation to x10/x100, x20/x200 or x50/x500. 

Thanks to the outstanding CMRR performance for differential and floating source measurements, the ADP probes in combination with their compact form factor are ideally suited for corresponding measurements in electromechanical and automotive engineering.

Features

  • Power supply via USB connection  or battery (optional)
  • Bandwidth: 100 MHz
  • Bandwidth limitation: 5 MHz / full
  • Out-of-range indicator/alarm
  • Double-layered probe cable for power insulation
  • EC conformity: EN 61010-031:2002 +A1:2008
  • Works for any DSO with USB port

Safety

ADP1025 and ADP1100 fulfil CAT I/II with a protective circuit up to 2500V, ADP2025 and ADP2100 fulfil CAT II/III with a protective circuit up to 4000V.

ADP5025 and ADP5100 fulfil CAT II/III with a protective circuit of 6000V. 

As the ADP probes, in contrast to probes with external power supply units, have a closed reinforced insulation, they do not require any additional earthing contacts. The oscilloscope itself must be earthed. The test leads of the ADP probes are double insulated. The ADP probes from Acute have been certified in accordance with the latest CAT I/II/III safety regulations.

The combination of galvanic isolation, protective insulation without additional earth contacts and power supply via USB port + laptop battery guarantees earth loop-free measurements. The double protective layer of the measuring cable (double-layer protection) guarantees a high level of protection for the user.

Technical Data

ModelADP-Tastköpfe-100MHz-small
ADP1100-U
acute-probe-small
ADP1100-B
ADP-Tastköpfe-100MHz-small
ADP2100-U
acute-probe-small
ADP2100-B
ADP-Tastköpfe-100MHz-small
ADP5100-U
acute-probe-small
ADP5100-B
Power supplyUSB PORTUSB/batteryUSB/BATTERYUSB/batteryUSB/BATTERYUSB/battery
Attenuation10X/100X10X/100X20X/200X20X/200X50X/500X50X/500X
Differential voltage700V (DC+ pk AC)700V (DC+ pk AC)1400V (DC+ pk AC) 1400V (DC+ pk AC)3500V (DC+ pk AC)3500V (DC+ pk AC)
Measurement categoriesCAT II 600V, CAT III 300VCAT II 600V, CAT III 300VCAT II 1000V, CAT III 600VCAT II 1000V, CAT III 600VCAT I 2300V, CAT III 1000V CAT I 2300V, CAT III 1000V