TH2830 Impedance analyser

The TH2830 is a compact, fast and extremely accurate impedance analyser with 20 Hz-10 MHz.

€899.00*

Volume discounts on request!

In Stock, Delivery time: 1 - 3 days

Further information
Request a quote
Paypal-icon
Mastercard-icon
visa-icon
klarna-icon
Sepa-lastschrift-icon
invoice-icon
Product number: TH2830

Description

The TH2830 is a compact, fast and extremely accurate impedance analyser with 20 Hz-10 MHz, auto-balance bridge technology, four-wire measurement, SCPI/RS-232/LAN interfaces and a large graphic LCD - ideal for testing components, materials and circuits.

Features

  • High accuracy: Auto-balance bridge technology, 4-pole pair
  • High stability and consistency: Up to 15 test ranges
  • High speed: Up to 7.7 ms
  • High resolution: 7 inch, 800 × 600
  • 201-point list sweep function
  • Multi-parameter graphic sweep function
  • Automatic polarity function for varactor diodes
  • 10-bins sorting, sorting result with audible and visual alarm
  • Memory capacity: Internal: 40 groups of setting files, USB, External: 500 groups of setting files, data log files and
  • Setting files, data log files and image files
  • Simultaneous check for Ls-RDC
  • High compatibility: Supports SCPI commands, compatible with KEYSIGHT E4980A, E4980AL, HP4284A, etc.

Applications

    • Passive components

      Estimation of impedance parameters and power analysis of capacitors, inductors, magnetic cores, resistors, piezoelectric components, transformers, chip components and network components
      Semiconductor components

      Test and analysis of parasitic parameters of integrated LED drivers.parameters of integrated LED driver circuits, C-V-DC properties of varactors, analysis of parasitic parameters of transistors or integrated circuits

    • Other components

      Impedance evaluation of printed circuit boards, relays, switches, cables, batteries

    • Dielectric materials

      Assessment of the dielectric constant and loss angle of plastics, ceramics and other materials

    • Magnetic materials

      Assessment of the magnetic permeability and loss angle of ferrites, amorphous bodies and other magnetic materials

    • Semiconductor materials

      Dielectric constant, electrical conductivity and C-V properties of semiconductor materials

    • Liquid crystal cells

      Dielectric constant, elasticity constant and C-V properties of liquid crystal cells

Technical Data

FeatureTH2839TH2839A
Measuring frequency20 Hz - 10 MHz20 Hz - 5 MHz
Basic accuracy±0,05 %±0,05 %
AC voltage signal5 mV - 2 V rms (≤ 2 MHz)
5 mV - 1 V rms (> 2 MHz)
5 mV - 2 V rms
AC current50 µA - 20 mA rms (≤ 2 MHz)
50 µA - 10 mA rms (> 2 MHz)
50 µA - 20 mA rms
DC bias voltage0 - ±40 V0 - ±40 V
DC bias current0 - ±100 mA0 - ±100 mA
External DC biasUp to ±120 V (with TH1778)Up to ±120 V (with TH1778)
Independent voltage source-10 V to +10 V-10 V to +10 V
Frequency resolution1 mHz1 mHz
Measuring speedFast: 7.7 ms, Medium: 120 ms, Slow: 230 msUp to 7.7 ms
Display7″ TFT, 800 × 600 px7″ TFT, 800 × 600 px
Display/sweep functionsList sweep (51-801 points), graphicList sweep, graphics
MemoryInternal: 40 settings; USB: 500 settings/data/imagesInternal: 40 settings; USB: 500 settings/data/images
Bridge technology4-wire measurement (auto-balance)4-wire measurement (auto-balance)
InterfacesUSB host, USB device, LAN, handler, RS-232C, optional GPIBUSB host, USB device, LAN, handler, RS-232C, optional GPIB
CompatibilitySCPI, Keysight E4980A/E4980AL, HP4284ASCPI, Keysight E4980A/E4980AL, HP4284A
Warm-up time60 minutes60 minutes
Mains voltage100-120 V / 198-242 V, 47-63 Hz100-120 V / 198-242 V, 47-63 Hz
Power consumptionapprox. 80 VAapprox. 80 VA
Dimensions (WxHxD)400 × 132 × 425 mm400 × 132 × 425 mm
Weight approxapprox. 15 kgapprox. 15 kg
Output impedance100 Ω100 Ω