Description
The Tonghui TH1912A millivoltmeter with 0.1 μV resolution enables the simultaneous display of main and secondary values such as dBm, %, Max/Min via a dual VFD display - ideal for use in production lines, repair workshops, training laboratories and automated test facilities.Features
- Frequency range: 5Hz-3MHz
- Measurement voltage range: 50μV-300V, resolution: 0.1μV
- Measured value display function: 4 1/2 digits VFD, dual display: the main display shows one measured value, and the secondary display can call up other measured values at will
- Absolute value: mV, V, W, dBm, dBV, dBmV, dBμV, Vp-p
- Relative value: dB, %, Max/Min
- Software menu setting: Measure power and dBm, set source load resistance as required
- Measurement dB,%, Max/Min Reference value setting
- Setting of ground (GND), float and safety warning
- Standard RS232C interface, support for SCPI command programming
Applications
- Workbench for production lines
- Repair workbench
- Teaching laboratory
- Automated test equipment
Technical Data
| Parameters | Specification |
|---|---|
| Current range | 0,1-50 A |
| Current resolution | 0,1 A |
| Frequency range | 1 Hz-2 MHz |
| Current rise/fall time | 1-20 A/s, freely adjustable |
| Min. scan step | 0,01 A |
| Max. Output voltage | 16 V |
| Max. permissible DC resistance | Rmax=Vmax/I |
| Max. permissible inductance | Lmax=Vmax/(di/dt) |
| Start/stop control | Physical buttons, bus, foot switch |
| Continuous measurement duration | Up to 30 min at full load |
| Self-test & function | Fault self-test; slave circuit; real-time operation; SCPI |
| Interfaces | RS232, SlaveLink |
| Operating temperature | 0 °C to 55 °C |
| Air humidity | < 90 % RH |
| Mains connection | AC 220 V/110 V ± 10 %, 50/60 Hz ± 5 % |
| Power consumption | Standby ≤ 100 VA; full load 1.5 kVA |
| Dimensions (W×H×D) | 430 × 177 × 585 mm |
| Weight | 26.5 kg |









.jpg)
.jpg)
.jpg)