Techmize TH2840B Precision LCR Meter

Product number: TH2840B
The TH2840B adds graphic sweep, C-V analysis and ±40 V bias. Characterise components, magnetics and dielectrics up to 2 MHz.
Volume discounts on request!

€4,751.10 Net

€5,653.81 incl. VAT

% €6,282.01* (10% saved)
Shipping country
Customer Group
Währung

Delivery time: 1 week

Model
Request a quote
Paypal-icon
Mastercard-icon
visa-icon
klarna-icon
Sepa-lastschrift-icon
invoice-icon
  • 2 year guarantee
Further information

Description

The Techmize TH2840B is a precision LCR meter for engineers who need to characterise components and materials well beyond audio frequencies. It measures from 20 Hz to 2 MHz with 0.05% basic accuracy, so you can follow capacitors, inductors and magnetic cores into the range of modern switching converters.

With a 20 Vrms test level (15 Vrms above 1 MHz), a ±40 V / ±100 mA DC bias, a built-in 2 A current source and graphic sweep, the TH2840B shows how impedance changes with frequency, signal level and bias, not just a single reading.

Key specifications

  • Test frequency: 20 Hz – 2 MHz
  • Basic accuracy: 0.05%
  • Speed: up to 1800 meas/s (0.56 ms, > 10 kHz)
  • Test level: 5 mVrms – 20 Vrms (≤ 1 MHz), up to 15 Vrms above 1 MHz; 50 µArms – 100 mArms
  • DC bias: 0 to ±40 V, 0 to ±100 mA; built-in 0 – 2 A current source
  • Display: 10.1" capacitive touch screen, 1280 × 800
  • Interfaces: LAN, USB Device, 2 × USB Host, RS232C, Handler, External DC bias control

Features

  • 2 MHz frequency range: characterise components and magnetics at switching frequencies, with frequency resolution down to 0.1 mHz at the low end.
  • Graphic sweep analysis: plot up to four parameters against frequency, AC level or DC bias, with 51 to 801 points, linear or log axes, 1, 2 or 4 screen layouts and cursor read-out.
  • C-V and bias characterisation: ±40 V / ±100 mA DC bias and a 2 A current source for varactor C-V curves and inductance under DC load. External DC bias control supports the TH1778A.
  • High test level: up to 20 Vrms (15 Vrms above 1 MHz) or 100 mArms, with constant-level ALC at the DUT.
  • Fast and repeatable: Fast+ mode at 0.56 ms per reading (1800 meas/s above 10 kHz), with no relay switching time.
  • 201-point list sweep: per-point averaging, delay, limits and sorting for multi-condition tests.
  • Sorting and automation: 10 bins plus PASS/FAIL, Handler output, LAN, USB (USBTMC) and RS232C for test systems.
  • Touch operation:1" 1280 × 800 touch screen, four parameters on screen, Linux-based system with built-in help.
  • Storage: 100 MB internal setup storage and USB stick storage for setups, screenshots and record files.

Applications

  • Magnetic materials: permeability and loss angle of ferrite and amorphous materials
  • Dielectric materials: dielectric constant and loss angle of plastics and ceramics
  • Semiconductor materials and devices: dielectric constant, conductivity and C-V characteristics; varactor C-Vdc; parasitic parameters of transistors, ICs and LED driver ICs
  • Liquid crystal cells: dielectric constant, elastic constant and C-V characteristics
  • Passive components: capacitors, inductors, cores, resistors, piezoelectric devices, transformers, chip and network components
  • Other components: PCBs, relays, switches, cables and batteries

Is the TH2840B right for you?

Choose the TH2840B when your work extends above 500 kHz or into material characterisation. For component testing up to 500 kHz, the Techmize TH2840A offers the same platform.

Technical Data

 

SpecificationTH2840A
TH2840A
TH2840B
TH2840B
Test frequency20 Hz – 500 kHz20 Hz – 2 MHz
Frequency resolution (highest band)1 Hz (100 – 500 kHz)10 Hz (1 – 2 MHz)
AC test voltage5 mVrms – 20 Vrms5 mVrms – 20 Vrms (≤ 1 MHz)
5 mVrms – 15 Vrms (> 1 MHz)
Basic accuracy0.05%0.05%
Frequency accuracy0.01%0.01%
Lowest frequency resolution0.1 mHz (20 – 99.9999 Hz)0.1 mHz (20 – 99.9999 Hz)
Measurement speedFast+ 0.56 ms (1800 meas/s, > 10 kHz)
Fast 3.3 ms / Medium 90 ms / Slow 220 ms
Fast+ 0.56 ms (1800 meas/s, > 10 kHz)
Fast 3.3 ms / Medium 90 ms / Slow 220 ms
AC voltage accuracy±(10% × set + 2 mV) ≤ 2 Vrms
±(10% × set + 5 mV) > 2 Vrms
±(10% × set + 2 mV) ≤ 2 Vrms
±(10% × set + 5 mV) > 2 Vrms
AC test current50 µArms – 100 mArms50 µArms – 100 mArms
Constant level (ALC)Voltage and currentVoltage and current
Output impedance30 Ω ±4% / 100 Ω ±2% @ 1 kHz30 Ω ±4% / 100 Ω ±2% @ 1 kHz
Rdc test voltage100 mV – 20 V100 mV – 20 V
DC bias voltage0 to ±40 V0 to ±40 V
DC bias current0 to ±100 mA0 to ±100 mA
Built-in current source0 – 2 A, 1 mA resolution0 – 2 A, 1 mA resolution
AC parametersCp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, Vac, IacCp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, Vac, Iac
DC parametersRdc, Vdc, IdcRdc, Vdc, Idc
Parameters on screen4, freely selectable4, freely selectable
Test terminalsFour-terminal pairFour-terminal pair
CorrectionOpen, Short, LoadOpen, Short, Load
List sweep201 points201 points
Graphic sweep51 – 801 points, up to 4 traces51 – 801 points, up to 4 traces
Comparator10 bins + PASS/FAIL, bin count 0 – 9999910 bins + PASS/FAIL, bin count 0 – 99999
Display10.1" touch screen, 1280 × 80010.1" touch screen, 1280 × 800
Internal storageApprox. 100 MB setup filesApprox. 100 MB setup files
InterfacesLAN, USB Device, 2 × USB Host, RS232C, Handler, Ext. DC bias controlLAN, USB Device, 2 × USB Host, RS232C, Handler, Ext. DC bias control
Power supply100 – 120 / 198 – 242 VAC, 47 – 63 Hz100 – 120 / 198 – 242 VAC, 47 – 63 Hz
Warm-up time60 min60 min
Dimensions (W × H × D)430 × 177 × 265 mm430 × 177 × 265 mm
Weight11 kg11 kg