€3,380.00*
- 3-year guarantee
- 2.5% advance payment discount
- If you use the payment method in advance by bank transfer, 2.5% of the purchase amount will be automatically deducted at the checkout.
Delivery time: 3-4 weeks
Description
The SDS3034X HD digital storage oscilloscope with a bandwidth of 350 MHz has 12-bit ADCs with a sampling rate of up to 4GSa/s, a maximum recording length of 400 Mpts/channel. This model displays up to 4 analogue and 16 digital channels for powerful mixed signal analysis.
Features
- 4 analogue channels, up to 1GHz bandwidth with up to 4GSa/s sampling rate
- 12-bit ADC
- Low background noise: 125μVrms at 1GHz bandwidth
- SPO technology
- Waveform capture rates of up to 200,000 wfm/sin in normal mode and 890,000 wfm/sin in sequence mode
- Supports 256-step intensity gradations and colour temperature display modes
- Up to 400 Mpts/channel recording length
- Digital trigger system
- Intelligent triggers: edge, slope, pulse, window, run, interval, dropout, pattern, qualified, Nth edge, setup/hold, delay and video
- Serial bus trigger and decoder, supports I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester andARINC429 protocols
- Segmented acquisition mode (sequence)
- Waveform history recording, the maximum length of the recorded waveform is 80,000 images
- Automatic measurements of more than 50 parameters, supports statistics with histogram, track, trend, gating measurement and measurements of maths, history and memory curves
- 4 mathematical tracks, supports formula editor
- Extensive data analysis functions such as search, navigation, digital voltmeter, counter, waveform histogram, Bode plot and power analysis
- High-speed hardware-based averaging, ERES; high-speed hardware-based mask test function
- 16 digital channels (optional)
- External 50MHz waveform generator (optional)
- 10.1" TFT LCD display (1024*600) with touchscreen
- Interfaces: 2x USB 3.0 host, 1x USB 2.0 host, USB 3.0 device (USBTMC), 1000M LAN (VXI-11/Telnet/Socket/LXI), external trigger input, aux output (pass/fail, trigger output)
- Built-in web server supports remote control via LAN connection with a web browser Supports SCPI remote control commands, NTP, and external mouse and keyboard
Hardware details
The SDS3000X HD series uses Siglent's SPO technology with a maximum waveform capture rate of up to 200,000 wfm/s, a 256-step intensity gradation display function and a colour temperature display mode. It also features an innovative digital trigger system with high sensitivity and low jitter. The trigger system supports several powerful trigger modes, including serial bus triggering. Tools such as history waveform recording, search and navigation functions, mask test, bode plot and power analysis allow extensive waveform recordings to be captured, stored and analysed. Other features of the SDS3000X HD include an impressive range of measurement and maths functions, options for a 50 MHz arbitrary waveform generator and serial decoding.
The large 10.1-inch capacitive touch screen supports multi-touch gestures and can significantly improve operational efficiency with its user-friendly UI design. It also supports mouse control and web remote control via LAN.
Product highlights
High waveform update rate
With a waveform update rate of up to 200,000 wfm/s, the oscilloscope can easily capture unusual or unlikely events. In sequence mode, the waveform capture rate can reach 890,000 wfm/s.
Deep record length
With the hardware-based zoom technique and a record length of up to 400 Mpts, the user can select a slower time base without compromising the sampling rate and then quickly zoom in to focus on the area of interest
Trigger functions
Edge, Slope, Pulse, Video, Windows, Runt, Interval, Dropout, Pattern, Qualified, Nth edge, Setup/hold, Delay and serial trigger
Extended mathematical function
In addition to the traditional operations (+, -, X, /), FFT, filter, integration, differential, square root and more are supported. A formula editor is available for more complex operations. There are 4 mathematical tracks available.
Measurements of a variety of parameters
The parameter measurements include 4 categories: Horizontal, Vertical, Miscellaneous and CH Delay, allowing a total of more than 50 different types of measurements. Measurements can be performed within a specific gate period. Measurements on mathematical, reference and history frames are supported.
History mode
The history function can record up to 80,000 images of waveforms. Recording is automatic, so the customer can replay the history waveforms at any time to observe unusual events and quickly locate the area of interest using the cursors or measurements. The failed frames of the mask test can be saved as a history.
Sequence mode
Segmented memory acquisition stores the waveform in multiple memory segments (up to 80,000) and each segment stores a triggered waveform and the dead time information. The interval between segments can be up to 1.12 μs. All segments can be played back using the history function
Searching and navigating
The oscilloscope can search for events specified by the user in a frame. Events marked by the search can be called up automatically with Navigate. It can also navigate by time (delay position) and history frame
Serial bus decoding
Display decoded characters via the event list. Bus protocol information can be displayed quickly and intuitively in tabular form. I2C, SPI, UART, CAN, LIN, CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester and ARINC429 are supported
Zone Trigger
Zone Trigger is available for advanced triggering. Combine spatial triggering with common trigger modes to isolate signals of interest
Bode Plot
The oscilloscope can drive SIGLENT's isolated USB AWG module or a standalone SIGLENT SDG generator to scan the amplitude and phase frequency response of the device under test and display the data as a Bode plot. This makes it possible to replace expensive network analysers in some applications.
Power analysis (optional)
The Power Analysis option offers a comprehensive range of power measurements and analyses that significantly improve measurement efficiency in the development of switching power supplies and power devices
Parameter statistics function
Statistics show the current value, maximum value, minimum value, standard deviation and mean value of up to 12 parameters simultaneously. A histogram is available to display the probability distribution of a parameter. For horizontal parameters such as the period, all results are extracted from a frame instead of just calculating the first one. This speeds up the statistics for horizontal measurements and allows observation of the distribution in a frame with histogram and track.
Hardware-based high-speed mask test function
The oscilloscope has a hardware-based mask test function that makes up to 28,000 pass/fail decisions per second. It is easy to create customised test templates to enable mask comparisons, making it suitable for long-term signal monitoring or automatic testing of production lines.
Deep Memory FFT
FFT supports operation with up to 4 Mpts. This enables high frequency resolution with a fast update rate. The FFT function also supports a variety of window functions so that it can adapt to different spectrum measurement requirements. Three modes (Normal, Average and Max hold) can fulfil different power spectrum observation requirements. Automatic peak detection and marker are supported.
Technical Data
Model comparison | SDS3034X HD | SDS3054X HD | SDS3104X HD |
---|---|---|---|
Analogue channels | 4 + EXT | 4 + EXT | 4 + EXT |
Bandwidth | 350 MHz | 500 MHz | 1 GHz (800 MHz in non-interleaving mode) |
Sampling rate (max.) | 4 GSa/s (interleaving mode), 2GSa/s (non-interleaving mode) | 4 GSa/s (interleaving mode), 2GSa/s (non-interleaving mode) | 4 GSa/s (interleaving mode), 2GSa/s (non-interleaving mode) |
Memory depth (max.) | 400 Mpts/channel (interleaving mode: single-channel) 200 Mpts/channel (interleaving mode: dual-channel) 100 Mpts/channel (non-interleaving mode | 400 Mpts/channel (interleaving mode: single-channel) 200 Mpts/channel (interleaving mode: dual-channel) 100 Mpts/channel (non-interleaving mode: single-channel) | 400 Mpts/channel (interleave mode: single channel) 200 Mpts/channel (interleave mode: dual channel) 100 Mpts/channel (non-interleave mode) |
Waveform capture rate (max.) | Normal mode:200,000 wfm/s Sequence mode:890,000 wfm/s | Normal mode:200,000 wfm/s Sequence mode:890,000 wfm/s | Normal mode:200,000 wfm/s Sequence mode:890,000 wfm/s |
Vertical resolution | 12-bit - up to 16-bit in ERES mode | 12-bit - up to 16-bit in ERES mode | 12-bit - up to 16-bit in ERES mode |
Trigger type | Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial | Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial | Edge, Slope, Pulse width, Window, Runt, Interval, Dropout, Pattern, Video, Qualified, Nth edge, Setup/hold, Delay, Serial |
Serial trigger and decoding | Standard: I2C, SPI, UART, CAN, LIN Optional: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester (decoding only), ARINC429 | Standard: I2C, SPI, UART, CAN, LIN Optional: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester (decoding only), ARINC429 | Standard: I2C, SPI, UART, CAN, LIN Optional: CAN FD, FlexRay, I2S, MIL-STD-1553B, SENT, Manchester (decoding only), ARINC429 |
Measurement | over 50 parameters, statistics, histogram, trend and track are supported | over 50 parameters, statistics, histogram, trend and track are supported | over 50 parameters, statistics, histogram, trend and track are supported |
Math | 4 traces 4 Mpts FFT, +, -, x, ÷, ∫dt, d/dt, √, Identity, Negation, Absolute, Sign, ex, 10x, ln, lg, Interpolation, MaxHold, MinHold, ERES, Average, Filter. | 4 traces 4 Mpts FFT, +, -, x, ÷, ∫dt, d/dt, √, Identity, Negation, Absolute, Sign, ex, 10x, ln, lg, Interpolation, MaxHold, MinHold, ERES, Average, Filter. | 4 traces 4 Mpts FFT, +, -, x, ÷, ∫dt, d/dt, √, Identity, Negation, Absolute, Sign, ex, 10x, ln, lg, Interpolation, MaxHold, MinHold, ERES, Average, Filter. |
Data analysis | Search, navigation, history, mask test, digital voltmeter, counter, waveform histogram, Bode plot and power analysis | Search, navigation, history, mask test, digital voltmeter, counter, waveform histogram, Bode plot and power analysis | Search, navigation, history, mask test, digital voltmeter, counter, waveform histogram, Bode plot and power analysis |
Digital channel (optional) | 16-channel; maximum sampling rate up to 1 GSa/s; recording length up to 100 Mpts | 16-channel; maximum sampling rate up to 1 GSa/s; recording length up to 100 Mpts | 16-channel; maximum sampling rate up to 1 GSa/s; recording length up to 100 Mpts |
Waveform generator (optional) | Single-channel SAG1021I, frequency up to 50 MHz, 125 MSa/s sampling rate, 16 kpts waveform memory | Single-channel SAG1021I, frequency up to 50 MHz, 125 MSa/s sampling rate, 16 kpts waveform memory | Single-channel SAG1021I, frequency up to 50 MHz, 125 MSa/s sampling rate, 16 kpts waveform memory |
I/O | USB 3.0 host x2, USB 2.0 host x1, USB 3.0 device, 10M/100M/1000M LAN, external trigger, auxiliary output | USB 3.0 host x2, USB 2.0 host x1, USB 3.0 device, 10M/100M/1000M LAN, external trigger, auxiliary output | USB 3.0 host x2, USB 2.0 host x1, USB 3.0 device, 10M/100M/1000M LAN, external trigger, auxiliary output |
Probe (standard) | Passive 500 MHz probe for each channel | Passive 500 MHz probe for each channel | Passive 500 MHz probe for each channel |
Display | 10.1 TFT LCD with capacitive touchscreen (1024*600) | 10.1 TFT LCD with capacitive touchscreen (1024*600) | 10.1 TFT LCD with capacitive touchscreen (1024*600) |